This paper presents dynamic thermal analysis of a power amplifier. All the investigations are based on the transient junction temperature measurements performed during the circuit cooling process. The presented results include the cooling curves, the structure functions, the thermal time constant distributions and the Nyquist plot of the thermal impedance. The experiments carried out desmonstrated the influence of the contact resistance and the position of the entire cooling assembly on the obtained results.